Notice: Function WP_Scripts::localize was called incorrectly. The $l10n parameter must be an array. To pass arbitrary data to scripts, use the wp_add_inline_script() function instead. Please see Debugging in WordPress for more information. (This message was added in version 5.7.0.) in /home/u126599030/domains/denismedicare.com/public_html/wp-includes/functions.php on line 6085
Notice: Function WP_Scripts::localize was called incorrectly. The $l10n parameter must be an array. To pass arbitrary data to scripts, use the wp_add_inline_script() function instead. Please see Debugging in WordPress for more information. (This message was added in version 5.7.0.) in /home/u126599030/domains/denismedicare.com/public_html/wp-includes/functions.php on line 6085
Notice: Function WP_Scripts::localize was called incorrectly. The $l10n parameter must be an array. To pass arbitrary data to scripts, use the wp_add_inline_script() function instead. Please see Debugging in WordPress for more information. (This message was added in version 5.7.0.) in /home/u126599030/domains/denismedicare.com/public_html/wp-includes/functions.php on line 6085
Notice: Function WP_Scripts::localize was called incorrectly. The $l10n parameter must be an array. To pass arbitrary data to scripts, use the wp_add_inline_script() function instead. Please see Debugging in WordPress for more information. (This message was added in version 5.7.0.) in /home/u126599030/domains/denismedicare.com/public_html/wp-includes/functions.php on line 6085
With flexible capacity and power choices
NP800/600 is designed for a variety of surgical
Chromic and traumatic wounds
NP800/600 Features
1. Pressure setting:- from – 25mmHg to -500 mmHg providing continuous intermittent and DPC therapy
2. Canisters:- 500ml
3. Protection with safety alarms for:-
Low battery
Canister full
Full canister/ line blockage
High/ low Vacuum
4. Cleaning drainage Therapy (NP – 800)
Manual cleaning (mode D)
Auto cleaning, Cleaning first (Mode – E)
Auto cleaning, Drainage first (mode – F)
5.NPWT with installation (NP – 800):-
Reduction of bioburden
Reduced pain at dressing change
Moisture balance in wound bed
6.Back hook for easily attaching to a bed, wheelchair or IV pole
7.High flow rate to ensure the performance under pressure
8.A wide range of exudates level can be dealt with two canister sizes
9.Low noise levels provide treatment in relaxation
Technical Features
Description:- NP800/600 Size (HxWxD):- 220x260x200mm Weight:- 4.33Kg Vacuum range:- -25 to -500 mmHg, -25,-50,-75,-100,-125,-150…….-500 Available Modes:- NP-600 continuous, intermittent and DPC
NP-800 Continuous, intermittent and DPC manual cleaning, auto cleaning, cleaning first, auto cleaning , drainage first Battery:- 6 hours , 5200mAh/7.4V Free air flow rate:- >8L/min Recharge times:- 6 hours Auto lockout:- Yes display lockout after 10 minutes or manually lock Canister:- 500ml, marking with 50ml increments Solidifier with canister:- Yes Display:- Display touch screen Antibacterial filter:- Yes Patients lockout:- Yes IV pole attachment:- Via strap Bed attachment:- Via strap Carry bag:- Yes Bluetooth:- Yes for mobile app monitor and control Alarm:- High/low vacuum , Canister full, low battery, Negative Pressure pump life cycle ends Alarm mute:- Yes Tubing Clamps:- Yes Power input:- Internal Lion battery or 110 – 240 AVC